Oil-Immersed Transformers Power Transformers SKU: 40_MVA_66KV_11KV_THREE_PHASE_OIL_IMMERSED_POWER_TRANSFORMER

40 MVA 66kV/11kV Three-Phase Oil-Immersed Power Transformer

This 40 MVA / three-phase oil-immersed power transformer is designed for utility substation, grid interconnection, and large industrial applications. Suitable for transmission and sub-transmission voltage classes. IEC 60076 design reference; ONAN/ONAF cooling options available. Manufactured and exported from Hefei, China.

Compliance Standards
IEC • ANSI • IEEE • GB
Quality Inspection
100% FAT Routine Tested
Engineering CAD
2D CAD / SLD Schematics
Global Logistics
Direct Seaport CIF Export
Engineering Datasheet

Technical Parameters & Ratings

IEC / ANSI Certified Factory Standard
Rated Capacity 40 MVA (40,000 kVA)
High Voltage 66.0 kV
Low Voltage 11.0 kV / customized
Frequency 50 Hz / 60 Hz
Phase Three Phase
Cooling Method ONAN / ONAF optional
Vector Group YNd11 / YNyn0 / customized
Tap Changer On-load tap changer (OLTC) / Off-circuit optional
Tapping Range +/-8 x 1.25% (OLTC) / +/-2 x 2.5% (OCTC)
Winding Material Copper
Core Material CRGO silicon steel, grain-oriented
Insulation Medium Mineral insulating oil
Standard IEC 60076 design reference
Installation Outdoor substation / indoor GIS substation

Application Scenarios

  • Utility substation step-down at / for distribution networks
  • Grid interconnection and power transmission projects in Africa and MENA
  • Large industrial facility main power supply transformers
  • EPC contractor packages for power plant auxiliary and grid connection

Key Features

  • 40 MVA rated capacity for utility substation and grid applications
  • high voltage class for sub-transmission and transmission grid interconnection
  • ONAN standard cooling with ONAF upgrade option for higher ambient temperature sites
  • On-load tap changer (OLTC) available for voltage regulation under load
  • Full copper windings with CRGO grain-oriented silicon steel core for low losses
XinHuan 40 MVA 66kV/11kV Three-Phase Oil-Immersed Power Transformer 2D AutoCAD General Arrangement Drawing Blueprint
Engineering Submittal Drawing

2D AutoCAD General Arrangement (GA) Drawing & Footprint

Official XinHuan factory 2D vector General Arrangement drawing for 40 MVA 66kV/11kV Three-Phase Oil-Immersed Power Transformer. Includes front elevation view, top plan view, terminal centerline clearances, base channel mounting footprint, and complete vector group connection schematics.

Dimensions ($L \times W \times H$ mm)
Terminal Centerline Clearances
Base Channel Mounting Pitch
Vector Group & Rating Plate
XinHuan Oil-Immersed Transformer Core Stacking & Assembly Workshop
XinHuan Hefei Manufacturing Plant — Precision Winding & Assembly Line
Factory Build Quality

Internal Construction & Premium Materials

Built with tier-1 certified raw materials engineered for long operational life (>30 years), superior dielectric withstand, and high short-circuit withstand capacity.

Silicon Steel Core

High-grade grain-oriented cold-rolled silicon steel with step-lap mitered joints for low $P_o$ losses.

100% Copper Windings

Electrolytic oxygen-free copper with high thermal grade insulation for surge resistance.

Precision Tap Changer

De-energized tap switch ($\pm 2 \times 2.5\%$) or on-load vacuum tap changer (OLTC) optional.

Protection & Sensors

Buchholz gas relay, magnetic oil gauge (MOG), and dial thermometers with alarm contacts.

Quality Assurance

100% Factory Acceptance Testing (FAT) Protocol

CNAS & ISO 9001 Certified

Every transformer unit manufactured by XinHuan undergoes mandatory routine factory testing prior to container dispatch. Full certified routine and type test submittal reports are provided with commercial documentation:

1. Insulation Resistance

Megger test (HV to LV, HV to Earth, LV to Earth) >1000 MΩ.

2. Voltage Ratio & Vector

Turns ratio check across all taps with phase displacement check.

3. Winding DC Resistance

Precision Kelvin bridge measurement across all tap positions.

4. Short-Circuit Impedance

Load loss ($P_k$) measurement corrected to reference temp (75°C).

5. No-Load Loss & Current

Core excitation test ($P_o$ and $I_o$) at rated sinusoidal voltage.

6. AC Voltage Withstand

Power-frequency separate source test (e.g. 50kV/70kV 1 min).

7. Lightning Impulse (BIL)

Full wave & chopped wave impulse withstand (BIL up to 170kV).

8. Partial Discharge & Seals

Ultra-low discharge (<5 pC) and pressurized oil/gas tightness test.

Logistics Intelligence

Export Packaging & Seaport Logistics

Global CIF / FOB Delivery

Large power transformers are shipped with oil-filled or oil-free transport options depending on voltage class and destination. All units include full documentation: routine test report, nameplate data, packing list, and certificate of origin. Lead time is confirmed at order stage based on specification complexity.

Production Lead Time

Standard manufacturing cycle is 4 to 6 weeks from approval of GA blueprints and single-line diagrams.

Heavy-Duty Export Packaging

Vacuum moisture barrier preservation, nitrogen blanketing, and reinforced steel-frame structural crate skids.

Direct Seaport Routes

Fast ocean freight to Port of Chancay & Callao (25-35 days), Manila, Lagos, and Middle East ports.

Equipment Video Inspection

100% Tested

Watch XinHuan technicians perform routine dielectric testing, winding insulation checks, and quality inspections inside our Hefei manufacturing plant.

Every unit 100% routine tested before container loading.
Direct Factory Consultation

Need Custom Project Engineering?

Send your single-line diagram (SLD), voltage ratings, or tender specifications. Our chief electrical engineers will review and issue an actionable CIF quotation within 24 hours.

Custom Voltage Ratios
High-Altitude Derating
Short-Circuit Impedance
Third-Party FAT Witness

Engineering & Procurement FAQs

Frequently asked questions regarding specifications, certifications, and delivery for 40 MVA 66kV/11kV Three-Phase Oil-Immersed Power Transformer.

Please send us your required MVA rating, primary voltage, secondary voltage, frequency (Hz), cooling class (ONAN/ONAF/OFAF), vector group, impedance, and installation site conditions. We will respond with a technical proposal and indicative pricing within 24 hours.

The product can be produced according to IEC 60076 and customer technical specifications for power transformer applications. Routine and type tests including temperature rise, impulse, and short-circuit withstand are available. Third-party witnessed testing can be arranged.

Standard manufacturing lead time is 4 to 6 weeks following approval of GA blueprints and single-line diagrams. Direct sea container shipping is available under FOB, CFR, or CIF terms with full customs documentation (Bill of Lading, Certificate of Origin, Test Reports).

Ready to Proceed?

Request a Firm Quotation for 40 MVA 66kV/11kV Three-Phase Oil-Immersed...

Share your project specifications and receive an official CIF quotation within 24 hours.