11kV Dry-Type Transformers — XinHuan transformer manufacturer China

Dry-Type Transformers · Special Voltage Dry-Type

11kV Dry-Type Transformers

This Google website content page groups 12 related product variants under one useful buyer page. Capacity is treated as a selectable variant, while the page focuses on 11kv dry-type transformers, project fit, specification decisions, and quotation requirements.

Selection Guide

How to specify 11kV Dry-Type Transformers

Focus on indoor transformer selection: insulation, enclosure, cooling, temperature rise, noise, and installation environment.

This Google website content page groups 12 related product variants under one useful buyer page. Capacity is treated as a selectable variant, while the page focuses on 11kv dry-type transformers, project fit, specification decisions, and quotation requirements.

Key Specifications

  • Capacity variants: 100 kVA, 250 kVA, 500 kVA, 1000 kVA

  • High voltage: 11kV

  • Low voltage: 220 V, 440 V, 480 V

  • Frequency: 50 Hz / 60 Hz

  • Cooling: AN natural air cooling

  • Application: Indoor distribution / commercial buildings / industrial power systems

Model Range

11kV Dry-Type Transformers — Configurations

Representative model

100 kVA 11kV/220V Three-Phase Dry Distribution Transformer

100 kVA 11kV/220V Three-Phase Dry Distribution Transformer; capacity: 100 kVA; HV: 11 kV; LV: 220 V; frequency: 50 Hz / 60 Hz

100 kVA 11kV/440V Three-Phase Dry Distribution Transformer

100 kVA 11kV/440V Three-Phase Dry Distribution Transformer; capacity: 100 kVA; HV: 11 kV; LV: 440 V; frequency: 50 Hz / 60 Hz

100 kVA 11kV/480V Three-Phase Dry Distribution Transformer

100 kVA 11kV/480V Three-Phase Dry Distribution Transformer; capacity: 100 kVA; HV: 11 kV; LV: 480 V; frequency: 50 Hz / 60 Hz

250 kVA 11kV/220V Three-Phase Dry Distribution Transformer

250 kVA 11kV/220V Three-Phase Dry Distribution Transformer; capacity: 250 kVA; HV: 11 kV; LV: 220 V; frequency: 50 Hz / 60 Hz

250 kVA 11kV/440V Three-Phase Dry Distribution Transformer

250 kVA 11kV/440V Three-Phase Dry Distribution Transformer; capacity: 250 kVA; HV: 11 kV; LV: 440 V; frequency: 50 Hz / 60 Hz

250 kVA 11kV/480V Three-Phase Dry Distribution Transformer

250 kVA 11kV/480V Three-Phase Dry Distribution Transformer; capacity: 250 kVA; HV: 11 kV; LV: 480 V; frequency: 50 Hz / 60 Hz

500 kVA 11kV/220V Three-Phase Dry Distribution Transformer

500 kVA 11kV/220V Three-Phase Dry Distribution Transformer; capacity: 500 kVA; HV: 11 kV; LV: 220 V; frequency: 50 Hz / 60 Hz

500 kVA 11kV/440V Three-Phase Dry Distribution Transformer

500 kVA 11kV/440V Three-Phase Dry Distribution Transformer; capacity: 500 kVA; HV: 11 kV; LV: 440 V; frequency: 50 Hz / 60 Hz

500 kVA 11kV/480V Three-Phase Dry Distribution Transformer

500 kVA 11kV/480V Three-Phase Dry Distribution Transformer; capacity: 500 kVA; HV: 11 kV; LV: 480 V; frequency: 50 Hz / 60 Hz

1000 kVA 11kV/220V Three-Phase Dry Distribution Transformer

1000 kVA 11kV/220V Three-Phase Dry Distribution Transformer; capacity: 1000 kVA; HV: 11 kV; LV: 220 V; frequency: 50...

1000 kVA 11kV/440V Three-Phase Dry Distribution Transformer

1000 kVA 11kV/440V Three-Phase Dry Distribution Transformer; capacity: 1000 kVA; HV: 11 kV; LV: 440 V; frequency: 50...

1000 kVA 11kV/480V Three-Phase Dry Distribution Transformer

1000 kVA 11kV/480V Three-Phase Dry Distribution Transformer; capacity: 1000 kVA; HV: 11 kV; LV: 480 V; frequency: 50...

RFQ Checklist

What to confirm before quotation

capacity
high voltage
low voltage
frequency
phase
application
installation environment
standard/reference requirement
drawing/document package
cooling
vector group
tap changer
winding material
accessories/monitoring

FAQ

11kV Dry-Type Transformers — Common Questions

To prepare an accurate quotation for 11kv dry-type transformers, please confirm: capacity, high voltage, low voltage, frequency, phase, application, installation environment, standard/reference requirement. Sharing a single-line diagram or specification sheet speeds up the response.

To prepare an accurate quotation for 11kv dry-type transformers, please confirm: capacity, high voltage, low voltage, frequency, phase, application, installation environment, standard/reference requirement. Sharing a single-line diagram or specification sheet speeds up the response.

Confirm the high-voltage and low-voltage ratings, the system frequency (50 Hz or 60 Hz), and the installation environment (indoor/outdoor, altitude, ambient temperature, corrosion). Typical range for this page — High voltage: 11kV; Frequency: 50 Hz / 60 Hz.

Cooling method, vector group, tap-changer type, winding material (copper/aluminium), and accessories/monitoring all affect design, price, and lead time. Configurable here — Cooling: AN natural air cooling.

Yes — 11kv dry-type transformers can be configured to project requirements (voltage ratio, cooling, vector group, tap range, accessories). Share your specification and we will confirm the design.

11kV Dry-Type Transformers — Get a Price

Send Your Specification

Include capacity (kVA), voltage ratio, frequency, installation conditions, destination country, and quantity. We respond within 24 hours.