This 3150 kva three-phase on-load tap changer (oltc) transformer is configured for a specific operating condition, application environment, or project requirement. It combines proven transformer platform design with targeted customization for winding material, environmental resistance, monitoring, voltage regulation, or special-duty performance according to export project needs.

Technical Specifications

Rated Capacity 3150 kVA
Primary Voltage (U1) 33,000 V (33 kV)
Secondary Voltage (U2) 415 V / 240 V (3-Phase 4-Wire)
Vector Group Dyn11
Rated Frequency 50 Hz
Cooling Method ONAN (Oil Natural Air Natural)
Primary Current (I1) 55.11 A
Secondary Current (I2) 4382.4 A
Guaranteed No-Load Loss (P0) 2800 W
Guaranteed Load Loss (Pk at 75°C) 21000 W
Short-Circuit Impedance (Uk) 5.0%
HV Insulation Level LI 170 / AC 70 (33kV Class)
Temperature Rise Limits Top Oil ≤ 50K, Winding ≤ 55K (45°C Ambient)
Creepage Distance ≥ 31 mm/kV (Outdoor Tropicalized Porcelain)
Core & Coil Weight 4500 kg
Insulating Oil Weight 2600 kg
Total Assembled Weight 8900 kg
Overall Footprint (L×W×H) 2300 mm × 1480 mm × 2400 mm
Governing Standards IEC 60076, BS 171, SON NIS, NERC Code

Equipment Video Walkthrough 100% Tested

Watch 100% factory routine testing & quality control inspections.

Pricing & Availability

Reference FOB Price

USD 32000

Public Marketplace Range

$17,600 – $33,500

Based on public listings. Often lead-generation or minimum-config prices — not full-scope.

Minimum Order

1 Set

Units in Stock

5

Model / Series

OLTC

Indicative export reference only. Final offer depends on voltage, standards, materials, accessories, and project scope. Request a firm quote →

Product Information

Status

Published

Product ID

3150_KVA_33KV_THREE_PHASE_ON_LOAD_TAP_CHANGER_OLTC_TRANSFORMER

Last Updated

2026-04-06 00:58:37.714818

Technical Highlights

  • This product combines dependable transformer platform design, flexible project configuration, and practical export-oriented construction. It is suitable for applications requiring stable electrical performance, configurable voltage ratios, outdoor durability, and documentation support for international project supply.

Application Scenarios

  • Utility distribution networks
  • Industrial plants and workshops
  • Commercial buildings and mixed-use developments
  • Public infrastructure projects
  • Regional and municipal power distribution systems

Key Features

  • Designed for electrical control, automation, and load-side switching functions
  • Configurable internal component arrangement according to process and feeder requirements
  • Supports communication, metering, and interface options for smart plant integration
  • Cabinet construction suitable for industrial and infrastructure environments
  • Project-oriented documentation, labeling, and wiring scheme support available
  • Suitable for export supply and customized control-package delivery

Optional Configurations

  • Low-voltage side rating and voltage ratio
  • Frequency: 50 Hz or 60 Hz
  • Vector group and tapping range
  • Copper or aluminum winding
  • Cooling method, accessory package, and monitoring option
  • Tank structure, coating system, and special environmental adaptation
  • Color, nameplate language, and document package
  • Ambient temperature, altitude, and installation condition adaptation

Internal Component Engineering Anatomy

High-precision 3D engineering cutaway model illustrating the core, windings, insulation, conservator tank, and protection accessories.

Oil-immersed transformer internal 3D cutaway model
High-Grade Silicon Core
Electrolytic Copper Windings
Tap Changer System
Buchholz & Temp Sensors
ion>
XinHuan 3150 kVA 33kV Three-Phase On-Load Tap Changer (OLTC) Transformer 2D AutoCAD General Arrangement Drawing Blueprint
Engineering Submittal Drawing

2D AutoCAD General Arrangement (GA) Drawing

Official XinHuan factory 2D vector General Arrangement drawing for 3150 kVA 33kV Three-Phase On-Load Tap Changer (OLTC) Transformer. Includes front elevation view, top plan view, bushing center-to-center distances, mounting hole footprint, and complete vector group layout.

Full Dimensions ($L \times W \times H$)
Bushing Terminal Distances
Mounting Base Footprint
Vector Group & Title Block

Frequently Asked Questions

Please send us your required capacity, high voltage, low voltage, frequency, cooling preference, and installation conditions for the 3150 kva three-phase on-load tap changer (oltc) transformer. Our team can recommend a suitable configuration and provide a quotation based on your project requirements.

The product can be produced according to IEC standards and customer technical specifications. Routine factory tests, inspection records, and technical documentation can be provided before shipment. Optional configurations for project-specific grid, environmental, and accessory requirements are available upon request.

Minimum order quantity is 1 Set. The product is prepared for export shipment with suitable packing and transport arrangements based on destination and handling requirements. Technical documents, test reports, nameplate confirmation, and pre-shipment support can be supplied according to order requirements. OEM/ODM support and project-based coordination are available for qualified inquiries.

Standards & Compliance

The product can be produced according to IEC standards and customer technical specifications. Routine factory tests, inspection records, and technical documentation can be provided before shipment. Optional configurations for project-specific grid, environmental, and accessory requirements are available upon request.

Packaging, Delivery & Service

The product is prepared for export shipment with suitable packing and transport arrangements based on destination and handling requirements. Technical documents, test reports, nameplate confirmation, and pre-shipment support can be supplied according to order requirements. OEM/ODM support and project-based coordination are available for qualified inquiries.

Please send us your required capacity, high voltage, low voltage, frequency, cooling preference, and installation conditions for the 3150 kva three-phase on-load tap changer (oltc) transformer. Our team can recommend a suitable configuration and provide a quotation based on your project requirements.

Ready to Proceed?

Request a Quote for 3150 kVA 33kV Three-Phase On-Load...

Share your project scope and we'll respond within 24 hours.