Oil-Immersed Transformers · Solar & Wind Step-Up

12500 kVA 35kV Solar Power Plant Step-Up Transformer

This 12500 kva solar power plant step-up transformer is designed for renewable energy interconnection, step-up duty, and grid-side distribution applications. It supports stable operation in solar, wind, photovoltaic, and energy-storage projects where flexible voltage ratios, reliable cooling, and project-oriented outdoor design are required.

Technical Specifications

Rated Capacity 2500 kVA
Primary Voltage (U1) 11,000 V (11 kV)
Secondary Voltage (U2) 415 V / 240 V (3-Phase 4-Wire)
Vector Group Dyn11
Rated Frequency 50 Hz
Cooling Method ONAN (Oil Natural Air Natural)
Primary Current (I1) 43.74 A
Secondary Current (I2) 3478.0 A
Guaranteed No-Load Loss (P0) 2300 W
Guaranteed Load Loss (Pk at 75°C) 17500 W
Short-Circuit Impedance (Uk) 5.0%
HV Insulation Level LI 75 / AC 35 (11kV Class)
Temperature Rise Limits Top Oil ≤ 50K, Winding ≤ 55K (45°C Ambient)
Creepage Distance ≥ 31 mm/kV (Outdoor Tropicalized Porcelain)
Core & Coil Weight 3600 kg
Insulating Oil Weight 2100 kg
Total Assembled Weight 7200 kg
Overall Footprint (L×W×H) 2100 mm × 1350 mm × 2200 mm
Governing Standards IEC 60076, BS 171, SON NIS, NERC Code

Equipment Video Walkthrough 100% Tested

Watch 100% factory routine testing & quality control inspections.

Pricing & Availability

Reference FOB Price

USD 151000

Public Marketplace Range

$68,000 – $166,000

Based on public listings. Often lead-generation or minimum-config prices — not full-scope.

Minimum Order

1 Set

Units in Stock

5

Model / Series

PV step-up

Indicative export reference only. Final offer depends on voltage, standards, materials, accessories, and project scope. Request a firm quote →

Product Information

Status

Published

Product ID

12500_KVA_35KV_SOLAR_POWER_PLANT_STEP_UP_TRANSFORMER

Last Updated

2026-04-06 00:58:37.300932

Technical Highlights

  • This product combines dependable transformer platform design, flexible project configuration, and practical export-oriented construction. It is suitable for applications requiring stable electrical performance, configurable voltage ratios, outdoor durability, and documentation support for international project supply.

Application Scenarios

  • Solar power plants
  • Wind farm collector and grid interface systems
  • Photovoltaic station and inverter interconnection projects
  • Battery energy storage systems (BESS)
  • Renewable energy substations and export EPC projects

Key Features

  • 12500 kVA rated capacity for renewable interconnection, step-up, or project-side power conversion
  • Designed for solar, wind, PV, or energy-storage power system applications
  • Configurable voltage ratio for inverter-side, collector-side, or grid-side connection
  • Oil-immersed construction for dependable cooling in outdoor renewable projects
  • Project-oriented accessory and monitoring options available
  • Suitable for IEC-based renewable projects and export EPC supply

Optional Configurations

  • Low-voltage side rating and voltage ratio
  • Frequency: 50 Hz or 60 Hz
  • Vector group and tapping range
  • Copper or aluminum winding
  • Cooling method, accessory package, and monitoring option
  • Tank structure, coating system, and special environmental adaptation
  • Color, nameplate language, and document package
  • Ambient temperature, altitude, and installation condition adaptation

Internal Component Engineering Anatomy

High-precision 3D engineering cutaway model illustrating the core, windings, insulation, conservator tank, and protection accessories.

Oil-immersed transformer internal 3D cutaway model
High-Grade Silicon Core
Electrolytic Copper Windings
Tap Changer System
Buchholz & Temp Sensors
ion>
XinHuan 12500 kVA 35kV Solar Power Plant Step-Up Transformer 2D AutoCAD General Arrangement Drawing Blueprint
Engineering Submittal Drawing

2D AutoCAD General Arrangement (GA) Drawing

Official XinHuan factory 2D vector General Arrangement drawing for 12500 kVA 35kV Solar Power Plant Step-Up Transformer. Includes front elevation view, top plan view, bushing center-to-center distances, mounting hole footprint, and complete vector group layout.

Full Dimensions ($L \times W \times H$)
Bushing Terminal Distances
Mounting Base Footprint
Vector Group & Title Block

Frequently Asked Questions

Please send us your required capacity, high voltage, low voltage, frequency, cooling preference, and installation conditions for the 12500 kva solar power plant step-up transformer. Our team can recommend a suitable configuration and provide a quotation based on your project requirements.

The product can be produced according to IEC standards and customer technical specifications. Routine factory tests, inspection records, and technical documentation can be provided before shipment. Optional configurations for project-specific grid, environmental, and accessory requirements are available upon request.

Minimum order quantity is 1 Set. The product is prepared for export shipment with suitable packing and transport arrangements based on destination and handling requirements. Technical documents, test reports, nameplate confirmation, and pre-shipment support can be supplied according to order requirements. OEM/ODM support and project-based coordination are available for qualified inquiries.

Standards & Compliance

The product can be produced according to IEC standards and customer technical specifications. Routine factory tests, inspection records, and technical documentation can be provided before shipment. Optional configurations for project-specific grid, environmental, and accessory requirements are available upon request.

Packaging, Delivery & Service

The product is prepared for export shipment with suitable packing and transport arrangements based on destination and handling requirements. Technical documents, test reports, nameplate confirmation, and pre-shipment support can be supplied according to order requirements. OEM/ODM support and project-based coordination are available for qualified inquiries.

Please send us your required capacity, high voltage, low voltage, frequency, cooling preference, and installation conditions for the 12500 kva solar power plant step-up transformer. Our team can recommend a suitable configuration and provide a quotation based on your project requirements.

Ready to Proceed?

Request a Quote for 12500 kVA 35kV Solar Power Plant...

Share your project scope and we'll respond within 24 hours.