This custom voltage three-phase oil distribution transformer is configured for a specific operating condition, application environment, or project requirement. It combines proven transformer platform design with targeted customization for winding material, environmental resistance, monitoring, voltage regulation, or special-duty performance according to export project needs.
| Rated Capacity | 1250 kVA |
|---|---|
| Primary Voltage (U1) | 11,000 V (11 kV) |
| Secondary Voltage (U2) | 415 V / 240 V (3-Phase 4-Wire) |
| Vector Group | Dyn11 |
| Rated Frequency | 50 Hz |
| Cooling Method | ONAN (Oil Natural Air Natural) |
| Primary Current (I1) | 21.87 A |
| Secondary Current (I2) | 1739.0 A |
| Guaranteed No-Load Loss (P0) | 1360 W |
| Guaranteed Load Loss (Pk at 75°C) | 9800 W |
| Short-Circuit Impedance (Uk) | 4.5% |
| HV Insulation Level | LI 75 / AC 35 (11kV Class) |
| Temperature Rise Limits | Top Oil ≤ 50K, Winding ≤ 55K (45°C Ambient) |
| Creepage Distance | ≥ 31 mm/kV (Outdoor Tropicalized Porcelain) |
| Core & Coil Weight | 1950 kg |
| Insulating Oil Weight | 1100 kg |
| Total Assembled Weight | 3850 kg |
| Overall Footprint (L×W×H) | 1750 mm × 1120 mm × 1850 mm |
| Governing Standards | IEC 60076, BS 171, SON NIS, NERC Code |
Official XinHuan factory 2D vector General Arrangement drawing for 10.5kV Custom Voltage Three-Phase Oil Distribution Transformer (1250kVA). Includes front elevation view, top plan view, terminal centerline clearances, base channel mounting footprint, and complete vector group connection schematics.
Built with tier-1 certified raw materials engineered for long operational life (>30 years), superior dielectric withstand, and high short-circuit withstand capacity.
High-grade grain-oriented cold-rolled silicon steel with step-lap mitered joints for low $P_o$ losses.
Electrolytic oxygen-free copper with high thermal grade insulation for surge resistance.
De-energized tap switch ($\pm 2 \times 2.5\%$) or on-load vacuum tap changer (OLTC) optional.
Buchholz gas relay, magnetic oil gauge (MOG), and dial thermometers with alarm contacts.
Every transformer unit manufactured by XinHuan undergoes mandatory routine factory testing prior to container dispatch. Full certified routine and type test submittal reports are provided with commercial documentation:
Megger test (HV to LV, HV to Earth, LV to Earth) >1000 MΩ.
Turns ratio check across all taps with phase displacement check.
Precision Kelvin bridge measurement across all tap positions.
Load loss ($P_k$) measurement corrected to reference temp (75°C).
Core excitation test ($P_o$ and $I_o$) at rated sinusoidal voltage.
Power-frequency separate source test (e.g. 50kV/70kV 1 min).
Full wave & chopped wave impulse withstand (BIL up to 170kV).
Ultra-low discharge (<5 pC) and pressurized oil/gas tightness test.
The product is prepared for export shipment with suitable packing and transport arrangements based on destination and handling requirements. Technical documents, test reports, nameplate confirmation, and pre-shipment support can be supplied according to order requirements. OEM/ODM support and project-based coordination are available for qualified inquiries.
Standard manufacturing cycle is 4 to 6 weeks from approval of GA blueprints and single-line diagrams.
Vacuum moisture barrier preservation, nitrogen blanketing, and reinforced steel-frame structural crate skids.
Fast ocean freight to Port of Chancay & Callao (25-35 days), Manila, Lagos, and Middle East ports.
Watch XinHuan technicians perform routine dielectric testing, winding insulation checks, and quality inspections inside our Hefei manufacturing plant.
Send your single-line diagram (SLD), voltage ratings, or tender specifications. Our chief electrical engineers will review and issue an actionable CIF quotation within 24 hours.
Frequently asked questions regarding specifications, certifications, and delivery for 10.5kV Custom Voltage Three-Phase Oil Distribution Transformer (1250kVA).
Ready to Proceed?
Share your project specifications and receive an official CIF quotation within 24 hours.