Finished Transformer Workshop
Real completed units staged in orderly rows, ready for final project inspection, FAT witnessing, and international dispatch.
Country Landing Page · Ghana
🇨🇳 Direct Hefei, China Factory Export to Ghana (Tema & Takoradi Ports). 50kVA–3150kVA 11kV & 33kV oil-immersed distribution transformers for ECG grid extension, VRA sub-station feeders, gold mining complexes, cocoa processing plants, and commercial EPC projects. No local middlemen markup — B2B factory-direct sea freight export with 100% IEC 60076 routine test submittals.
Reference: XH-2026.
Our engineering team is preparing your proposal and CIF pricing.
Factory Facility & Verification
Direct visual proof of XinHuan's manufacturing capability in Hefei, China. Unedited photographs showing our finished distribution transformer workshop, marked finished products area, cast resin dry-type stock, and export container loading.
Real completed units staged in orderly rows, ready for final project inspection, FAT witnessing, and international dispatch.
F/H-class cast resin coils and harmonic mitigation dry-type distribution transformers in stock.
Clear production-stage segregation and routine quality verification for procurement teams prior to container packaging.
Precision silicon steel core stacking, copper coil winding assembly, and tank fabrication.
Heavy-duty vacuum autoclave drying process ensuring zero residual moisture in coil insulation.
Direct container packing and heavy-duty ocean freight loading outside our Hefei facility.
Quality & Compliance
Every transformer, compact substation, and switchgear unit is engineered under audited ISO quality management systems and type-tested according to IEC 60076 and ANSI C57 international standards.
Certified Quality Management System covering design, coil winding, vacuum drying, oil filling, and routine testing of 10kV–35kV distribution transformers.
Environmental Management System certifying low-loss eco-designed core assemblies, zero PCB insulation oil, and environmentally safe production controls.
Occupational Health and Safety Management System ensuring safety containment in high-voltage testing bays and factory assembly protocols.
Complete routine and type test records (temperature rise, impulse voltage withstand, short-circuit withstand) conducted at CNAS-accredited national research institutes.
On-site factory audit certificate by SGS / Made-in-China, verifying manufacturing premises, export capacity, assembly lines, and legal qualification.
Verified annual supply performance and delivery certificate for overseas power grid EPC and industrial infrastructure projects (Mozambique, Nigeria, Kenya, SEA).
Ghana Market Focus
XinHuan is a China-based power transformer manufacturer exporting directly from our Hefei production facility to Ghana via Tema Port and Takoradi Port. We engineer 50Hz oil-immersed distribution transformers and cast-resin dry-type units aligned with Electricity Company of Ghana (ECG) utility standards, Volta River Authority (VRA) grid connection rules, and Ghana Standards Authority (GSA) certification guidelines.
We supply 50kVA to 3150kVA distribution transformers across Ghana's standard 11kV and 33kV primary medium-voltage distribution networks with 415V/240V (3-phase 4-wire) secondary output. Engineered for West Africa's tropical climate, our transformers feature heavy-duty IP54/IP55 weather-sealed tanks, Dyn11 vector groups, ONAN cooling, and low-loss silicon steel cores designed for gold mining sites in Obuasi and Tarkwa, cocoa processing plants in Kumasi, and commercial high-rises in Accra.
| Product | Oil-Immersed Distribution Transformer |
|---|---|
| Voltage | 11kV / 33kV |
| Capacity | 50kVA–2500kVA |
| Frequency | 50Hz |
| Phase | Three phase |
| Cooling | ONAN (Oil Natural Air Natural) |
| Insulation | Class A Mineral Oil |
| Enclosure | Hermetically Sealed Corrugated Tank |
| Standard | IEC 60076 / ANSI C57.12.00 |
| Vector group | Dyn11 / Yyn0 / customized |
| Tap changer | Off-circuit tap changer (±2×2.5%) |
| Winding | Copper / aluminum |
| LV voltage | 0.4kV / 0.415kV / customized |
| Installation | Outdoor pad-mount / pole-mount / indoor |
Choose a Starting Model
These are real XinHuan product records selected for the 11kV / 33kV, 50kVA to 3150kVA scope for Ghana projects. Open a model to compare its build, then request an exact project configuration.
Oil-Immersed Transformers · Distribution
250kVA Utility and Commercial Range
A practical mid-range option for distribution upgrades, compounds, and commercial facilities with moderate load growth.
This 250 kVA oil-immersed distribution transformer is designed for dependable power distribution in utility, industrial, and commercial networks....
Oil-Immersed Transformers · Distribution
400kVA Mining and Industrial Feeder
A strong fit for mining auxiliaries, process loads, and industrial sites that need dependable 33kV distribution support.
This 400 kVA oil-immersed distribution transformer is designed for reliable power distribution in rural utility networks, industrial feeders, and...
Oil-Immersed Transformers · Distribution
1000kVA Expansion Projects
Suitable for larger estates, industrial expansions, and project substations with higher load concentration.
This 1000 kVA oil-immersed distribution transformer is designed for dependable power distribution in utility, industrial, and commercial networks....
Local Market Notes
Ghana enquiries commonly come from utility distribution, mining, factory expansion, and commercial property projects that need practical export support.
Tema and Takoradi routing should be locked early because inland trucking, unloading space, and project schedule can affect packing decisions.
Mining and industrial buyers often check accessory scope carefully, including temperature indication, surge protection, and cable termination arrangement.
Procurement Notes
Send the required voltage ratio, kVA, vector group, and installation environment so we can align the quotation with the actual feeder layout.
Tell us whether the project needs a bare transformer only or a broader package with switchgear, metering, or compact-substation coordination.
If internal approval is required, ask for outline drawing, routine test scope, and delivery packing details in the first quotation round.
Quote Checklist
Voltage class, LV output, and tap range
Unit rating and total project quantity
Mining, utility, solar, or industrial application
Tema or Takoradi delivery target
Accessory scope and enclosure requirements
Drawing, approval, and documentation needs
Engineering Submittal & Layout Workbench
Select your equipment type and capacity to inspect verified GA engineering CAD line drawings, Single Line Diagrams (SLD), dimensions (L × W × H), roller gauge, and submittal clearances before procurement.
International utility & industrial submittal specifications
| Overall Length (L) | 1,750 mm |
|---|---|
| Overall Width (W) | 1,120 mm |
| Overall Height (H) | 1,780 mm |
| Roller Wheel Track Gauge (D) | 820 mm |
| Total Equipment Net Weight | 3,820 kg |
| Min Substation Clearance | 1,000 mm surrounding |
| Rated Voltage / System | 11 kV / 33 kV Dual Primary |
| Applicable Standard | IEC 60076-1 / IEEE C57 |
Full CAD DXF/DWG vector footprints, 3D STEP models, and custom project submittals provided within 2 hours upon request.
Reference Visuals
Regional Delivery Reference
Helpful for Ghana utility and industrial buyers comparing the physical build and export finish of oil-immersed distribution units.
Regional Product Reference
A transformer-specific reference for Ghana buyers comparing tank construction, bushings, radiator layout, and factory finish.
Tender & Approval Support
Outline drawing, technical datasheet, and accessory confirmation
Routine test references and approval-ready quotation details
Commercial and packing documents for Tema or Takoradi routing
Optional coordination notes for switchgear, panel, or substation package scope
Tell us about any drawing, packing, or accessory requirements in the first RFQ. Detailed design drawings and final approval documents are scoped after commercial terms and project requirements are agreed.
Applications
ECG distribution feeder injection & VRA medium-voltage network expansion
Gold mining (Obuasi, Tarkwa, Tarkwa Bay) industrial substation power supply
Cocoa processing, timber milling & industrial manufacturing plant distribution
Cast resin dry-type transformers (IP20/IP23) for commercial high-rises & hospital vaults in Accra
EPC contractor project scope with CIF Tema/Takoradi ocean freight & complete export test packages
Delivery & Ports
Direct ocean freight shipping to Tema Port (Accra/Kumasi) and Takoradi Port (Western Region) with complete export documentation, GSA alignment support, and customs clearance submittals.
Common Ghana project requirements include 250kVA, 500kVA, 800kVA, and 1000kVA 11kV/0.415kV & 33kV/0.415kV units for industrial estate distribution, mining auxiliaries, and feeder injection substations.
Why XinHuan
Factory-direct quotation support eliminating local trading markup for Ghanaian EPC contractors and industrial buyers
Full compliance with ECG / VRA 11kV & 33kV primary grid standards with 415V 4-wire secondary output
Tropicalized design with IP54 outdoor protection, high-efficiency silicon steel core, and ONAN cooling
Complete export documentation package (GSA clearance alignment, IEC 60076 Routine Test Reports, CAD Dimension Drawings)
Project Fit
Utility feeders, mining loads, solar distribution, factory supply, and EPC project power systems.
Standard page scope: oil-immersed distribution transformers, 11kV / 33kV, 50kVA–1000kVA, three phase, 50Hz, ONAN cooling, copper/aluminum winding options, Dyn11 / Yyn0 / customized vector group, off-circuit tap changer, and outdoor or indoor installation.
Factory & Testing
Factory tours, transformer testing, and production walkthroughs straight from our Hefei manufacturing base.
Hefei manufacturing base, automated workshops, and high-voltage testing laboratory.
100% IEC 60076 voltage ratio, winding resistance, and dielectric routine testing.
Epoxy resin vacuum casting, partial discharge testing, and temperature monitoring.
Compact outdoor substation assembly with loop-feed and dead-front safety design.
Automated coil winding, precision core stacking, and vacuum drying chambers.
Vacuum circuit breakers, copper busbar routing, and relay protection cabinets.
Prefabricated kiosk substation panel wiring, RMU integration, and LV distribution.
Copper foil winding, vacuum resin casting molds, and core-coil assembly.
Engineering Quality Assurance
All XinHuan transformers undergo 100% factory routine testing, dielectric voltage withstand tests, and partial discharge inspection before dispatch.
Engineering Submittal Package
Need CAD outline packs or type test reports for consultant approval in Ghana?
Request Technical CAD & Spec PackSpecialized Substation & Power
Explore specialized XinHuan power equipment solutions for emergency substations, SF6 gas-insulated distribution, and renewable BESS energy storage.
Trailer and skid-mounted mobile substations with integrated HV/LV switchgear, protection panels, and fast-coupling terminals for emergency grid restoration and remote mining.
Hermetically sealed 12kV SF6 gas-insulated compact switchgear and Ring Main Unit (RMU) for urban distribution vaults, indoor substations, and harsh environments.
Specialized inverter-duty step-up transformers with K-factor harmonic isolation and split low-voltage windings for utility-scale solar PV and BESS battery storage plants.
Related Internal Links
Use the nearest matching page for specifications, category browsing, or quotation follow-up.
Ghana RFQ CTA
Send your primary voltage (11kV / 33kV), kVA capacity, target installation site, and destination port (Tema/Takoradi) for an immediate factory CIF quote.
FAQ
Yes, our transformers for Ghana are engineered for 50Hz frequency, 11kV / 33kV primary voltage, and 415V 4-wire secondary output in full compliance with ECG guidelines.
We support Ghana Standards Authority (GSA) product verification requirements and provide all necessary pre-shipment inspection certificates.
Common primary distribution ratings in Ghana are 11kV and 33kV, with standard capacities ranging from 100kVA to 2500kVA.
Yes, we supply complete Routine Test Certificates (IEC 60076), CAD dimension submittals, and schematic diagrams for engineer/consultant approval.
Ocean shipping from China to Tema or Takoradi ports typically takes 30-40 days direct.
Send your kVA rating, voltage ratio (e.g. 33kV/0.415kV), vector group, and destination port for an immediate factory CIF quote.
Direct Contact & Instant RFQ
Contact us directly via WhatsApp, email, or fill out the quick RFQ form below for a fast response from our engineering team.
Reference ID:
Our engineering and export team will email or WhatsApp you detailed technical drawings and CIF pricing within 2 hours.