ISO 9001:2015 품질 시스템
10kV~35kV 배전 변압기의 설계, 코일 권선, 진공 건조, 오일 충전 및 일상 테스트를 포괄하는 인증된 품질 관리 시스템입니다.
Procurement Guide
Complete engineering guide for specifying prefabricated compact substations (11kV / 22kV / 33kV) for EPC contractors, industrial parks, utility distribution, and renewable energy projects. Compliant with IEC 62271-202.
Prefabricated compact substations (also known as package substations, kiosk substations, or outdoor transformer stations) combine medium-voltage switchgear, a step-down distribution transformer, and low-voltage distribution panels inside a single factory-tested, pre-wired, weatherproof housing.
By integrating all three electrical compartments into a factory skid, compact substations reduce site civil installation time from 3 months down to 2 days, saving up to 45% in total project installed costs for EPC contractors and utility developers.
As a direct compact substation factory in China, XinHuan manufactures both European package substations and American pad-mounted configurations with factory-direct pricing, routine FAT testing, and rapid export delivery worldwide.
Standard dimensions, weights, and thermal ratings according to IEC 62271-202. Available in walk-in, non-walk-in, or underground vault configurations.
| 정격 용량(kVA) | 고전압(kV) | LV Outgoing Outlets | Approx Dimensions L×W×H (mm) | Approx Weight (kg) | Thermal Enclosure Class |
|---|---|---|---|---|---|
| 100 kVA | 11 / 22 / 33 | 2 Way MCCB | 2,200 × 1,600 × 2,100 | 2,400 kg | Class 10 / Class 15 |
| 250 kVA | 11 / 22 / 33 | 2–4 Way MCCB | 2,400 × 1,800 × 2,200 | 3,100kg | Class 10 / Class 15 |
| 500 kVA | 11 / 22 / 33 | 4–6 Way MCCB | 2,800 × 2,000 × 2,400 | 4,500 kg | Class 10 / Class 15 |
| 800 kVA | 11 / 22 / 33 | 6 Way MCCB | 3,200 × 2,200 × 2,500 | 5,800kg | Class 10 / Class 15 |
| 1000 kVA | 11 / 22 / 33 | 6–8 Way MCCB | 3,600 × 2,300 × 2,600 | 6,900 kg | Class 10 / Class 15 |
| 1250 kVA | 11 / 22 / 33 | 8 Way MCCB / ACB | 4,000 × 2,400 × 2,700 | 8,200 kg | Class 10 / Class 15 |
| 1600 kVA | 11 / 22 / 33 | 8–10 Way MCCB / ACB | 4,500 × 2,500 × 2,800 | 10,500 kg | Class 15 / Class 20 |
| 2000 kVA | 11 / 22 / 33 | 10–12 Way ACB | 5,000 × 2,600 × 2,900 | 12,800 kg | Class 15 / Class 20 |
| 2500 kVA | 11 / 22 / 33 | 12 Way ACB / APFC | 5,600 × 2,800 × 3,000 | 15,400 kg | Class 20 |
| 3150 kVA | 11 / 22 / 33 | 12–16 Way ACB | 6,200 × 3,000 × 3,200 | 18,900 kg | Class 20 |
| 특징 | European Package Substation (IEC 62271-202) | American Pad-Mounted (IEEE C57.12.28) |
|---|---|---|
| Compartment Layout | 3 Separate Steel Doors (MV RMU, Transformer, LV) | Dead-front cabinet attached directly to transformer tank |
| MV 배전반 유형 | SF6 Gas-Insulated RMU or Vacuum Switchgear | Internal loadbreak switches & bay-o-net fuses |
| 용량 범위 | 100 kVA to 3150 kVA | 45 kVA to 5000 kVA |
| 변압기 유형 | Oil-immersed or Dry-type (Cast Resin) | Oil-immersed (Mineral or FR3 vegetable oil) |
| 인클로저 보호 | IP23 / IP33 (Trans) & IP54 (RMU / LV) | NEMA 3R Tamper-resistant cabinet |
| Primary Regional Market | Middle East, Africa, Europe, Asia, Latin America | North America, Central America, Philippines |
Houses 11kV, 22kV, or 33kV Ring Main Unit (RMU) switchgear with SF6 gas or eco-friendly air insulation. Includes loadbreak switches, vacuum circuit breakers, cable testing bushings, and relay protection.
Houses a high-efficiency oil-immersed (ONAN) or cast-resin dry-type (AN) transformer with natural louvered ventilation, vibration isolation pads, oil retention tray, and thermal sensors.
Houses main MCCB/ACB circuit breakers, copper busbars, current transformers (CTs), dual-tariff energy meters, surge arresters, and optional automatic power factor correction (APFC) capacitor banks.
Safety for operators and the public is paramount. XinHuan package substations are internal-arc tested according to IEC 62271-202 IAC AB 20kA 1s. In the rare event of an internal arc fault, internal pressure relief flaps channel hot arc gases downward into the civil cable trench, preventing door blowout or lateral gas projection.
Installing a prefabricated compact substation requires minimal site preparation compared to traditional brick-and-mortar substations:
Calculate kVA load sizing or evaluate IEC loss cost lifecycle savings for your substation project.
Custom 3-compartment layout, single-line diagrams (SLD), and FOB/CIF price delivery in 24h.
Get Substation Quote →품질 및 규정 준수
모든 변압기, 소형 변전소 및 스위치기어 장치는 감사를 받은 ISO 품질 관리 시스템에 따라 설계되었으며 IEC 60076 및 ANSI C57 국제 표준에 따라 유형 테스트를 거쳤습니다.
10kV~35kV 배전 변압기의 설계, 코일 권선, 진공 건조, 오일 충전 및 일상 테스트를 포괄하는 인증된 품질 관리 시스템입니다.
저손실 친환경 설계 코어 어셈블리, 제로 PCB 절연유 및 환경적으로 안전한 생산 관리를 인증하는 환경 관리 시스템입니다.
산업 보건 및 안전 관리 시스템은 고전압 테스트 베이 및 공장 조립 프로토콜의 안전 격리를 보장합니다.
CNAS 공인 국가 연구 기관에서 수행된 완전한 루틴 및 유형 테스트 기록(온도 상승, 임펄스 전압 내구성, 단락 내구성).
제조 현장, 수출 능력, 조립 라인 및 법적 자격을 검증하는 SGS/Made-in-China의 현장 공장 감사 인증서입니다.
해외 전력망 EPC 및 산업 인프라 프로젝트(모잠비크, 나이지리아, 케냐, SEA)에 대한 연간 공급 실적 및 납품 인증서를 검증했습니다.