Metropolitan Central General Hospital

Hospital Operating Suite Isolated Power System & Medical-Grade IT Transformers

Medical-grade IT isolation transformers with ultra-low leakage current (<200µA), Faraday electrostatic shielding, and insulation monitoring for hospital operating rooms and ICUs.

Industry Sector
Healthcare Infrastructure
Equipment Scope
10 kVA to 50 kVA
Primary Voltage
220V / 220V Single-Phase & 380V Three-Phase
Compliance Standard
IEC 60076 / IEEE / ANSI
Hospital Operating Suite Isolated Power System & Medical-Grade IT Transformers
Project Installation Visual — Metropolitan Central General Hospital

1. Project Context & Operational Challenge

Medical operating rooms, intensive care units (ICUs), and cardiac cath labs demand ungrounded Medical IT power distribution per IEC 60364-7-710 to guarantee zero micro-shock risk to patients and continuous power during first line-to-earth electrical faults.

2. Customized Engineering Solution

XinHuan manufactured custom Medical-Grade IT System Isolation Transformers featuring double Nomex insulation, copper Faraday electrostatic shield grounded between primary and secondary windings, built-in PT100 temperature sensors, and ultra-low leakage current (<150µA).

Ultra-Low Leakage Current <150µA
Protects sensitive surgical and life-support equipment from stray leakage currents.
Faraday Electrostatic Shielding
Blocks high-frequency grid noise, voltage spikes, and electromagnetic interference.
IEC 60364-7-710 Compliance
Certified to international medical electrical safety & hospital isolation standards.
Integrated Insulation Monitor
Real-time insulation resistance monitoring with remote nurse-station alarm consoles.

3. Installed Equipment Parameters & Ratings

Parameter Specification Design Rating & Certified Value
Power Rating 3.15 kVA – 50 kVA
Voltage Ratio 220V / 220V or 380V / 220V
Insulation Class Class H (180°C)
Leakage Current to Ground < 150 µA (Certified)
Inrush Current Peak < 12 x In
Standard Certification IEC 60364-7-710 / DIN VDE 0100-710
Audible Noise < 35 dB (Silent Medical Operation)

4. Project Outcomes & Field Performance

Successfully commissioned across 24 operating suites and intensive care units, achieving 100% compliance with hospital electrical safety audits.

EPC Consultant Verification
"XinHuan delivered complete routine test certificates, CAD submittal drawings, and CIF seaport freight within schedule. The transformer passed all site acceptance testing (SAT) on first energized commissioning."
Direct Factory Quotation

Need a Similar Technical Submittal?

Our engineering team provides 2D AutoCAD General Arrangement drawings, electrical parameter submittals, and CIF seaport quotes within 24 hours.


Matching Product SKUs