Field-Proven Engineering Track Record

B2B Engineering Project Case Studies

Discover how XinHuan custom power distribution transformers, 110kV mobile substations, and GIS switchgear deliver 99.99% uptime in harsh environments — from 3,850m high-altitude mines to utility grid restorations.

50+ Export Countries 100% FAT Certified 30+ Years Operational Life

Featured Global Installations

Verified technical project briefs with engineering parameters, site challenges, and results.

Submit Your Project RFQ
5 MVA 33kV High-Altitude Mining Transformer Substation in Andes Copper Mine, Peru
Mining & Metallurgy
Arequipa Region, Peru (Elevation 3,850m ASL)

5 MVA 33kV High-Altitude Mining Transformer Substation in Andes Copper Mine, Peru

Custom high-altitude engineered 5 MVA 33kV power transformer with high creepage distance bushings (>31mm/kV), derated cooling, and IP54 outdoor protection for continuous Andes copper mining operations.

Rating / Scope: 5000 kVA (5 MVA)
Primary Voltage: 33 kV / 0.48 kV
2500 kVA Solar PV Step-Up Substation Package in Atacama Desert, Chile
Renewable Solar Energy
Atacama Desert, Antofagasta, Chile

2500 kVA Solar PV Step-Up Substation Package in Atacama Desert, Chile

Low-loss 2500 kVA 33kV solar step-up transformer package engineered for high UV, extreme sandstorm abrasion, and 60Hz Chilean utility grid integration.

Rating / Scope: 2500 kVA (2.5 MVA)
Primary Voltage: 33 kV / 0.69 kV
31.5 MVA 110kV Semi-Trailer Mounted Mobile Substation for Emergency Utility Grid Restoration
Power Utility & Infrastructure
Regional Transmission & Distribution Feeder Network

31.5 MVA 110kV Semi-Trailer Mounted Mobile Substation for Emergency Utility Grid Restoration

Rapid-deployment 31.5 MVA 110kV mobile substation trailer with integrated SF6 GIS switchgear, OLTC power transformer, and digital protection relay system for instant emergency power restoration.

Rating / Scope: 31.5 MVA (31,500 kVA)
Primary Voltage: 110 kV / 13.8 kV
Hospital Operating Suite Isolated Power System & Medical-Grade IT Transformers
Healthcare Infrastructure
Metropolitan Central General Hospital

Hospital Operating Suite Isolated Power System & Medical-Grade IT Transformers

Medical-grade IT isolation transformers with ultra-low leakage current (<200µA), Faraday electrostatic shielding, and insulation monitoring for hospital operating rooms and ICUs.

Rating / Scope: 10 kVA to 50 kVA
Primary Voltage: 220V / 220V Single-Phase & 380V Three-Phase
Custom OEM Engineering

Have a High-Capacity Substation or Custom Project Requirement?

Our sales engineering team provides custom technical submittals, 2D AutoCAD GA drawings, vector group wiring diagrams, and direct CIF seaport freight quotes within 24 hours.