Switchgear & Control Gas-Insulated Switchgear (GIS / RMU) SKU: 12KV_GAS_INSULATED_SWITCHGEAR_RING_MAIN_UNIT_RMU

XinHuan 12Kv Gas Insulated Switchgear Ring Main Unit Rmu (IEC / GB Certified)

Factory-direct gas insulated switchgear ring main unit rmu engineered for utility distribution and industrial power projects. 100% factory routine and type tested with fast global delivery.

Compliance Standards
IEC • ANSI • IEEE • GB
Quality Inspection
100% FAT Routine Tested
Engineering CAD
2D CAD / SLD Schematics
Global Logistics
Direct Seaport CIF Export
Engineering Datasheet

Technical Parameters & Ratings

Print Submittal Datasheet IEC / ANSI Certified Factory Standard
Rated Voltage 12 kV / 24 kV
Rated Frequency 50 Hz / 60 Hz
Rated Normal Current (Busbar) 630 A / 1250 A
Rated Normal Current (Feeder/Breaker) 630 A
Short-Time Withstand Current (4s) 20 kA / 25 kA (4s)
Peak Withstand Current 50 kA / 63 kA (Ip)
Power Frequency Withstand Voltage (1min) 42 kV (phase-to-earth) / 48 kV (isolating distance)
Lightning Impulse Withstand (BIL) 75 kV / 95 kV / 125 kV peak
Gas Tank Ingress Protection IP67 (Gas Tank) / IP4X (Outer Enclosure)
Outer Enclosure Protection IP4X Indoor / IP54 Outdoor Option
Insulation Medium SF6 Gas / Eco-Friendly Gas Optional
Annual Leakage Rate < 0.1% per year (30+ Year Maintenance-Free Design)
Operating Temperature Range -40°C to +50°C
Modular Functional Units C (Load Break Switch), V (Vacuum Circuit Breaker), F (Switch-Fuse), CVC, CCV, CCF, CCC
Standards Compliance IEC 62271-200, GB/T 3906

Application Scenarios

  • Wind & solar PV renewable collector substations, urban underground distribution vaults, commercial high-rises, and industrial plant ring feeds.

Features

  • Hermetically sealed 3.0mm 304 stainless steel gas tank protects all live high-voltage components against flooding, humidity, dust, and aggressive industrial fumes (IP67).
  • Modular flexibility supporting extensible and compact non-extensible configurations (CVC, CCV, CCF, V, C, F) for smart ring distribution networks.
  • Maintenance-free vacuum circuit breaker (VCB) and 3-position disconnect/earthing switch with mechanical interlocks for foolproof operator safety.

Standards

  • Type-tested to IEC 62271-200:2021 with certified routine test reports (FAT), gas tightness certification, and 100% X-ray weld inspection.

Engineering Submittal & Layout Workbench

Substation Room Fit & Multi-Equipment CAD Footprints

Select your equipment type and capacity to inspect verified GA engineering CAD line drawings, Single Line Diagrams (SLD), dimensions (L × W × H), roller gauge, and submittal clearances before procurement.

Available Ratings:
IEC 60076-1 Submittal Specs
XinHuan Engineering GA CAD Drawing
XinHuan Engineering Single Line Diagram (SLD)
11kV / 33kV Dual Voltage
IEC 60076 / IEEE Compliant
100% Routine Factory Tested
Export Nitrogen / Seaworthy Pack

1000 kVA Technical Dimensions

IEC 60076-1

International utility & industrial submittal specifications

Overall Length (L) 1,750 mm
Overall Width (W) 1,120 mm
Overall Height (H) 1,780 mm
Roller Wheel Track Gauge (D) 820 mm
Total Equipment Net Weight 3,820 kg
Min Substation Clearance 1,000 mm surrounding
Rated Voltage / System 11 kV / 33 kV Dual Primary
Applicable Standard IEC 60076-1 / IEEE C57
Download Technical Data Sheet (PDF) Request Factory Engineering Submittal Package

Full CAD DXF/DWG vector footprints, 3D STEP models, and custom project submittals provided within 2 hours upon request.

XinHuan Prefabricated Substation and Switchgear Assembly Line
XinHuan Hefei Manufacturing Plant — Precision Winding & Assembly Line
Factory Build Quality

Internal Construction & Premium Materials

Built with tier-1 certified raw materials engineered for long operational life (>30 years), superior dielectric withstand, and high short-circuit withstand capacity.

Silicon Steel Core

High-grade grain-oriented cold-rolled silicon steel with step-lap mitered joints for low $P_o$ losses.

100% Copper Windings

Electrolytic oxygen-free copper with high thermal grade insulation for surge resistance.

Precision Tap Changer

De-energized tap switch ($\pm 2 \times 2.5\%$) or on-load vacuum tap changer (OLTC) optional.

Protection & Sensors

Buchholz gas relay, magnetic oil gauge (MOG), and dial thermometers with alarm contacts.

Quality Assurance

100% Factory Acceptance Testing (FAT) Protocol

CNAS & ISO 9001 Certified

Every transformer unit manufactured by XinHuan undergoes mandatory routine factory testing prior to container dispatch. Full certified routine and type test submittal reports are provided with commercial documentation:

1. Insulation Resistance

Megger test (HV to LV, HV to Earth, LV to Earth) >1000 MΩ.

2. Voltage Ratio & Vector

Turns ratio check across all taps with phase displacement check.

3. Winding DC Resistance

Precision Kelvin bridge measurement across all tap positions.

4. Short-Circuit Impedance

Load loss ($P_k$) measurement corrected to reference temp (75°C).

5. No-Load Loss & Current

Core excitation test ($P_o$ and $I_o$) at rated sinusoidal voltage.

6. AC Voltage Withstand

Power-frequency separate source test (e.g. 50kV/70kV 1 min).

7. Lightning Impulse (BIL)

Full wave & chopped wave impulse withstand (BIL up to 170kV).

8. Partial Discharge & Seals

Ultra-low discharge (<5 pC) and pressurized oil/gas tightness test.

Logistics Intelligence

Export Packaging & Seaport Logistics

Global CIF / FOB Delivery

Export seaworthy packaging with nitrogen pre-charge, moisture-proof barrier, and reinforced steel-frame containment. Typical production lead time: 4–6 weeks from drawing approval.

Production Lead Time

Standard manufacturing cycle is 4 to 6 weeks from approval of GA blueprints and single-line diagrams.

Heavy-Duty Export Packaging

Vacuum moisture barrier preservation, nitrogen blanketing, and reinforced steel-frame structural crate skids.

Direct Seaport Routes

Fast ocean freight to Port of Chancay & Callao (25-35 days), Manila, Lagos, and Middle East ports.

Equipment Video Inspection

100% Tested

Watch XinHuan technicians perform routine dielectric testing, winding insulation checks, and quality inspections inside our Hefei manufacturing plant.

Every unit 100% routine tested before container loading.
Direct Factory Consultation

Need Custom Project Engineering?

Send your single-line diagram (SLD), voltage ratings, or tender specifications. Our chief electrical engineers will review and issue an actionable CIF quotation within 24 hours.

Custom Voltage Ratios
High-Altitude Derating
Short-Circuit Impedance
Third-Party FAT Witness

Engineering & Procurement FAQs

Frequently asked questions regarding specifications, certifications, and delivery for XinHuan 12Kv Gas Insulated Switchgear Ring Main Unit Rmu (IEC / GB Certified).

Please specify rated capacity (kVA), primary/secondary voltages, frequency (50/60Hz), standard (IEC/ANSI), cooling type, site altitude, and target destination port.

Manufactured and type-tested in accordance with IEC 62271-200:2021, IEC 62271-100, and GB/T 3906. Certified factory routine test report (FAT) and SF6 pressure inspection certificate supplied with every unit.

Standard manufacturing lead time is 4 to 6 weeks following approval of GA blueprints and single-line diagrams. Direct sea container shipping is available under FOB, CFR, or CIF terms with full customs documentation (Bill of Lading, Certificate of Origin, Test Reports).

Ready to Proceed?

Request a Firm Quotation for XinHuan 12Kv Gas Insulated Switchgear...

Share your project specifications and receive an official CIF quotation within 24 hours.