R-Core & Audio Transformers R-Core Power Transformers SKU: XH_R40_TS4390A_TUBE_PREAMP_R_CORE_TRANSFORMER

R40-TS4390A 40VA Tube Preamplifier R-Core Power Transformer

40VA specialized vacuum tube preamplifier R-Core power transformer (Model R40-TS4390A). Features annealed OFC copper perimeter flux shielding, 220V primary with ground lead, high-voltage center-tapped secondary (200V-0V-200V / 0.04A) for vacuum tube plate supply, dual 6.3V filament windings (1A & 1.5A), and 8V / 1.3A auxiliary supply. Certified zero hum and <5 mG stray flux leakage.

Compliance Standards
IEC • ANSI • IEEE • GB
Quality Inspection
100% FAT Routine Tested
Engineering CAD
2D CAD / SLD Schematics
Global Logistics
Direct Seaport CIF Export
Engineering Datasheet

Technical Parameters & Ratings

Print Submittal Datasheet IEC / ANSI Certified Factory Standard
Power Rating 40 VA
Model Number R40-TS4390A
Primary Input 220 VAC 50/60Hz (Red-Red Leads)
Earth Ground / Shield Yellow/Green Ground Lead connected to OFC Annealed Copper Band
Secondary High-Voltage B+ 200V - 0V - 200V / 0.04A (Yellow - Green - Yellow Center-Tapped)
Secondary Filament Rail 1 6.3 VAC / 1.0A (Orange-Orange)
Secondary Filament Rail 2 6.3 VAC / 1.5A (White-White)
Secondary Auxiliary Rail 8.0 VAC / 1.3A (Blue-Blue)
Core Construction Nippon Steel High-Permeability Silicon Strip Continuous Circular Core
Magnetic Flux Leakage < 5 mG (Near-Zero Stray Field, Ideal for Sensitive Phono/Preamp Stages)
Shielding Band Heavy Annealed OFC Oxygen-Free Copper Foil Perimeter Band
Dielectric Withstand 4,000 V AC Primary-Secondary Test Passed
Dimensions (L×W×H) 84 × 74 × 50 mm
Mounting Centers 74 × 58 mm
Net Weight 0.85 kg
Factory Hotline 13696514019 / Hefei XinHuan Transformer Co., Ltd.

Technical Highlights

  • Outer perimeter wrapped with authentic annealed OFC oxygen-free copper foil shielding band to prevent 50Hz/60Hz electromagnetic hum pick-up in high-gain tube stages.

Application Scenarios

  • Class-A tube preamplifiers, moving-magnet/moving-coil phono preamps, headphone amplifiers, and vintage audio restorations.

Key Features

  • 40VA audiophile vacuum tube preamplifier transformer with high-voltage B+ secondary (200V-0V-200V @ 40mA center-tapped).
  • Dual dedicated 6.3V filament heater rails (6.3V 1.0A + 6.3V 1.5A) designed specifically for 12AX7, 12AU7, 6SN7, and 6922 vacuum tubes.
  • Auxiliary 8.0V 1.3A rail for rectified relay control, display circuitry, or solid-state input selector stages.

Engineering Submittal & Layout Workbench

Substation Room Fit & Multi-Equipment CAD Footprints

Select your equipment type and capacity to inspect verified GA engineering CAD line drawings, Single Line Diagrams (SLD), dimensions (L × W × H), roller gauge, and submittal clearances before procurement.

Available Ratings:
IEC 60076-1 Submittal Specs
XinHuan Engineering GA CAD Drawing
XinHuan Engineering Single Line Diagram (SLD)
11kV / 33kV Dual Voltage
IEC 60076 / IEEE Compliant
100% Routine Factory Tested
Export Nitrogen / Seaworthy Pack

1000 kVA Technical Dimensions

IEC 60076-1

International utility & industrial submittal specifications

Overall Length (L) 1,750 mm
Overall Width (W) 1,120 mm
Overall Height (H) 1,780 mm
Roller Wheel Track Gauge (D) 820 mm
Total Equipment Net Weight 3,820 kg
Min Substation Clearance 1,000 mm surrounding
Rated Voltage / System 11 kV / 33 kV Dual Primary
Applicable Standard IEC 60076-1 / IEEE C57
Download Technical Data Sheet (PDF) Request Factory Engineering Submittal Package

Full CAD DXF/DWG vector footprints, 3D STEP models, and custom project submittals provided within 2 hours upon request.

XinHuan Oil-Immersed Transformer Core Stacking & Assembly Workshop
XinHuan Hefei Manufacturing Plant — Precision Winding & Assembly Line
Factory Build Quality

Internal Construction & Premium Materials

Built with tier-1 certified raw materials engineered for long operational life (>30 years), superior dielectric withstand, and high short-circuit withstand capacity.

Silicon Steel Core

High-grade grain-oriented cold-rolled silicon steel with step-lap mitered joints for low $P_o$ losses.

100% Copper Windings

Electrolytic oxygen-free copper with high thermal grade insulation for surge resistance.

Precision Tap Changer

De-energized tap switch ($\pm 2 \times 2.5\%$) or on-load vacuum tap changer (OLTC) optional.

Protection & Sensors

Buchholz gas relay, magnetic oil gauge (MOG), and dial thermometers with alarm contacts.

Quality Assurance

100% Factory Acceptance Testing (FAT) Protocol

CNAS & ISO 9001 Certified

Every transformer unit manufactured by XinHuan undergoes mandatory routine factory testing prior to container dispatch. Full certified routine and type test submittal reports are provided with commercial documentation:

1. Insulation Resistance

Megger test (HV to LV, HV to Earth, LV to Earth) >1000 MΩ.

2. Voltage Ratio & Vector

Turns ratio check across all taps with phase displacement check.

3. Winding DC Resistance

Precision Kelvin bridge measurement across all tap positions.

4. Short-Circuit Impedance

Load loss ($P_k$) measurement corrected to reference temp (75°C).

5. No-Load Loss & Current

Core excitation test ($P_o$ and $I_o$) at rated sinusoidal voltage.

6. AC Voltage Withstand

Power-frequency separate source test (e.g. 50kV/70kV 1 min).

7. Lightning Impulse (BIL)

Full wave & chopped wave impulse withstand (BIL up to 170kV).

8. Partial Discharge & Seals

Ultra-low discharge (<5 pC) and pressurized oil/gas tightness test.

Logistics Intelligence

Export Packaging & Seaport Logistics

Global CIF / FOB Delivery

Factory direct foam carton packaging. Worldwide express courier or air freight.

Production Lead Time

Standard manufacturing cycle is 4 to 6 weeks from approval of GA blueprints and single-line diagrams.

Heavy-Duty Export Packaging

Vacuum moisture barrier preservation, nitrogen blanketing, and reinforced steel-frame structural crate skids.

Direct Seaport Routes

Fast ocean freight to Port of Chancay & Callao (25-35 days), Manila, Lagos, and Middle East ports.

Equipment Video Inspection

100% Tested

Watch XinHuan technicians perform routine dielectric testing, winding insulation checks, and quality inspections inside our Hefei manufacturing plant.

Every unit 100% routine tested before container loading.
Direct Factory Consultation

Need Custom Project Engineering?

Send your single-line diagram (SLD), voltage ratings, or tender specifications. Our chief electrical engineers will review and issue an actionable CIF quotation within 24 hours.

Custom Voltage Ratios
High-Altitude Derating
Short-Circuit Impedance
Third-Party FAT Witness

Engineering & Procurement FAQs

Frequently asked questions regarding specifications, certifications, and delivery for R40-TS4390A 40VA Tube Preamplifier R-Core Power Transformer.

Inquire with your required filament and B+ high voltage rail requirements for custom winding adjustments.

Manufactured to IEC 61558-1 / UL 5085 standards. 4,000V AC dielectric withstand tested. Flame retardant Class B insulation.

Standard manufacturing lead time is 4 to 6 weeks following approval of GA blueprints and single-line diagrams. Direct sea container shipping is available under FOB, CFR, or CIF terms with full customs documentation (Bill of Lading, Certificate of Origin, Test Reports).

Ready to Proceed?

Request a Firm Quotation for R40-TS4390A 40VA Tube Preamplifier R-Core...

Share your project specifications and receive an official CIF quotation within 24 hours.