R-Core & Audio Transformers R-Core Power Transformers SKU: XH_R30_E8208_EXPORT_R_CORE_TRANSFORMER

R30-E8208 / ECTHF 18821 30VA Export R-Core Power Transformer

30VA factory certified export R-Core power transformer manufactured by Anhui BuJuan Overseas Info-Tech / XinHuan. Dual 110VAC 50Hz/60Hz universal primary (series 220V/230V or parallel 110V), multi-rail isolated secondary (24VAC 0.5A, dual 13.5VAC 0.8A, 6VAC 1A), electrostatic Faraday shield grounding lead, and black insulated outer wrapper.

Compliance Standards
IEC • ANSI • IEEE • GB
Quality Inspection
100% FAT Routine Tested
Engineering CAD
2D CAD / SLD Schematics
Global Logistics
Direct Seaport CIF Export
Engineering Datasheet

Technical Parameters & Ratings

Print Submittal Datasheet IEC / ANSI Certified Factory Standard
Power Rating 30 VA
Model Number R30-E8208 / ECTHF 18821
Input Voltage Dual 110VAC 50Hz (Red-Black & Yellow-Green, Series 220V / Parallel 110V)
Secondary Output 1 24 VAC / 0.5A (Gray-Gray)
Secondary Output 2 13.5 VAC / 0.8A (Blue-Blue)
Secondary Output 3 13.5 VAC / 0.8A (White-White)
Secondary Output 4 6 VAC / 1.0A (Green-Green)
Electrostatic Shield Faraday Copper Shield (Yellow/Green Earth Ground)
Core Construction Continuous Grain-Oriented Nippon Steel Silicon Ribbon (Gapless R-Core)
Dielectric Isolation 4,000 V AC Primary-to-Secondary / Core (1 Minute)
Temperature Rise < 30K under continuous full rated load
Dimensions (L×W×H) 78 × 68 × 46 mm
Mounting Hole Distance 68 × 52 mm (M4 Galvanized Footplate)
Net Weight 0.68 kg
Manufacturer & Export Entity ANHUI BUJUAN OVERSEAS INFO-TECH CO., LTD. / Hefei XinHuan Transformer Co., Ltd.

Technical Highlights

  • Continuous grain-oriented silicon core exhibits zero mechanical hum, <5 mG stray magnetic leakage, and superior line regulation.

Application Scenarios

  • Audiophile DACs, CD player power supplies, reference solid-state preamps, and medical lab instrumentation.

Key Features

  • Export-certified R-core power transformer with dual 110VAC universal primary (series 220V or parallel 110V configuration).
  • Precision quad-rail secondary windings (24V 0.5A + dual 13.5V 0.8A + 6V 1A) engineered for high-end audio DACs and preamplifiers.
  • Built-in Faraday electrostatic copper shield with dedicated yellow/green earth lead eliminates high-frequency mains interference.

Engineering Submittal & Layout Workbench

Substation Room Fit & Multi-Equipment CAD Footprints

Select your equipment type and capacity to inspect verified GA engineering CAD line drawings, Single Line Diagrams (SLD), dimensions (L × W × H), roller gauge, and submittal clearances before procurement.

Available Ratings:
IEC 60076-1 Submittal Specs
XinHuan Engineering GA CAD Drawing
XinHuan Engineering Single Line Diagram (SLD)
11kV / 33kV Dual Voltage
IEC 60076 / IEEE Compliant
100% Routine Factory Tested
Export Nitrogen / Seaworthy Pack

1000 kVA Technical Dimensions

IEC 60076-1

International utility & industrial submittal specifications

Overall Length (L) 1,750 mm
Overall Width (W) 1,120 mm
Overall Height (H) 1,780 mm
Roller Wheel Track Gauge (D) 820 mm
Total Equipment Net Weight 3,820 kg
Min Substation Clearance 1,000 mm surrounding
Rated Voltage / System 11 kV / 33 kV Dual Primary
Applicable Standard IEC 60076-1 / IEEE C57
Download Technical Data Sheet (PDF) Request Factory Engineering Submittal Package

Full CAD DXF/DWG vector footprints, 3D STEP models, and custom project submittals provided within 2 hours upon request.

XinHuan Oil-Immersed Transformer Core Stacking & Assembly Workshop
XinHuan Hefei Manufacturing Plant — Precision Winding & Assembly Line
Factory Build Quality

Internal Construction & Premium Materials

Built with tier-1 certified raw materials engineered for long operational life (>30 years), superior dielectric withstand, and high short-circuit withstand capacity.

Silicon Steel Core

High-grade grain-oriented cold-rolled silicon steel with step-lap mitered joints for low $P_o$ losses.

100% Copper Windings

Electrolytic oxygen-free copper with high thermal grade insulation for surge resistance.

Precision Tap Changer

De-energized tap switch ($\pm 2 \times 2.5\%$) or on-load vacuum tap changer (OLTC) optional.

Protection & Sensors

Buchholz gas relay, magnetic oil gauge (MOG), and dial thermometers with alarm contacts.

Quality Assurance

100% Factory Acceptance Testing (FAT) Protocol

CNAS & ISO 9001 Certified

Every transformer unit manufactured by XinHuan undergoes mandatory routine factory testing prior to container dispatch. Full certified routine and type test submittal reports are provided with commercial documentation:

1. Insulation Resistance

Megger test (HV to LV, HV to Earth, LV to Earth) >1000 MΩ.

2. Voltage Ratio & Vector

Turns ratio check across all taps with phase displacement check.

3. Winding DC Resistance

Precision Kelvin bridge measurement across all tap positions.

4. Short-Circuit Impedance

Load loss ($P_k$) measurement corrected to reference temp (75°C).

5. No-Load Loss & Current

Core excitation test ($P_o$ and $I_o$) at rated sinusoidal voltage.

6. AC Voltage Withstand

Power-frequency separate source test (e.g. 50kV/70kV 1 min).

7. Lightning Impulse (BIL)

Full wave & chopped wave impulse withstand (BIL up to 170kV).

8. Partial Discharge & Seals

Ultra-low discharge (<5 pC) and pressurized oil/gas tightness test.

Logistics Intelligence

Export Packaging & Seaport Logistics

Global CIF / FOB Delivery

Export carton with custom-molded high-density foam cushioning. Global express DHL/FedEx or palletized sea freight dispatch.

Production Lead Time

Standard manufacturing cycle is 4 to 6 weeks from approval of GA blueprints and single-line diagrams.

Heavy-Duty Export Packaging

Vacuum moisture barrier preservation, nitrogen blanketing, and reinforced steel-frame structural crate skids.

Direct Seaport Routes

Fast ocean freight to Port of Chancay & Callao (25-35 days), Manila, Lagos, and Middle East ports.

Equipment Video Inspection

100% Tested

Watch XinHuan technicians perform routine dielectric testing, winding insulation checks, and quality inspections inside our Hefei manufacturing plant.

Every unit 100% routine tested before container loading.
Direct Factory Consultation

Need Custom Project Engineering?

Send your single-line diagram (SLD), voltage ratings, or tender specifications. Our chief electrical engineers will review and issue an actionable CIF quotation within 24 hours.

Custom Voltage Ratios
High-Altitude Derating
Short-Circuit Impedance
Third-Party FAT Witness

Engineering & Procurement FAQs

Frequently asked questions regarding specifications, certifications, and delivery for R30-E8208 / ECTHF 18821 30VA Export R-Core Power Transformer.

Contact engineering with your required secondary voltage rails and jumper preferences for same-day CAD drawing confirmation.

Manufactured in compliance with IEC 61558-1, IEC 61558-2-4, UL 5085, CE, RoHS. 100% dielectric withstand hi-pot tested at 4,000V AC.

Standard manufacturing lead time is 4 to 6 weeks following approval of GA blueprints and single-line diagrams. Direct sea container shipping is available under FOB, CFR, or CIF terms with full customs documentation (Bill of Lading, Certificate of Origin, Test Reports).

Ready to Proceed?

Request a Firm Quotation for R30-E8208 / ECTHF 18821 30VA Export...

Share your project specifications and receive an official CIF quotation within 24 hours.