12kV High-Voltage Vacuum Circuit Breakers (VCB) — XinHuan transformer manufacturer China

Product Category — Circuit Breakers & Apparatus

12kV High-Voltage Vacuum Circuit Breakers (VCB)

XinHuan manufactures high-performance 12kV indoor vacuum circuit breakers (XH-VCB-12) and outdoor pole-mounted boundary load break switches (XH-FZW-12). Designed for KYN28 switchgear cubicles, industrial substations, and overhead feeder automation.

12 kV
rating
31.5 kA
breaking capacity
10,000 Ops
mechanical life
IEC 62271
tiêu chuẩn

Tổng quan kỹ thuật

High-End Vacuum Interrupter & Switching Apparatus

Vacuum circuit breakers (VCBs) are the core switching and protective devices inside medium-voltage power systems. By extinguishing electrical arcs inside hermetically sealed ceramic vacuum interrupters, VCBs deliver zero maintenance and long electrical endurance.

Features include solid-embedded pole construction, withdrawable handcart mechanisms for KYN28 switchgear panels, and smart FTU controller integration for outdoor boundary pole switches.

Thông số kỹ thuật chính

  • Điện áp định mức

    12 kV

  • Dòng điện định mức

    630 A / 1250 A / 2500 A / 3150 A

  • Short-Circuit Breaking Current

    20 kA / 25 kA / 31.5 kA / 40 kA

  • Mechanical Endurance

    10,000 Operations (Class M2)

  • Tiêu chuẩn

    IEC 62271-100 / GB 1984

Dải sản phẩm

12kV High-Voltage Vacuum Circuit Breakers (VCB) — 1 Models Available

Showing a selection from XinHuan's 12kv high-voltage vacuum circuit breakers (vcb) range. Xem toàn bộ danh mục →

12kV Indoor High-Voltage Vacuum Circuit Breaker

Circuit Breakers & Apparatus · Indoor Circuit Breakers

12kV Indoor High-Voltage Vacuum Circuit Breaker

High-reliability indoor vacuum circuit breaker (VCB) with modular spring operating mechanism. Ideal for...

3D Engineering Anatomy Cutaway

High-precision 3D component breakdown illustrating core assembly, copper windings, insulation, conservator tank, and protection accessories.

12kV High-Voltage Vacuum Circuit Breakers (VCB) internal 3D cutaway engineering model
High-Grade Silicon Core
Electrolytic Copper Coil
Off-Circuit / OLTC Tap Switch
Buchholz & Temp Relays

Factory Quality Inspection & Testing

Watch routine factory testing and quality control inspections inside XinHuan's manufacturing facility.

100% full routine tests (IEC 60076) conducted before export packing.

Technical Q&A

Frequently Asked Questions — 12kV High-Voltage Vacuum Circuit Breakers (VCB)

XinHuan's 12kV High-Voltage Vacuum Circuit Breakers (VCB) units are manufactured strictly to IEC 60076 and GB/T 1094 standards (or ANSI C57.12 upon request). Every unit undergoes full factory routine tests: winding resistance, voltage ratio, phase displacement, short-circuit impedance, load/no-load losses, and separate-source AC withstand voltage.

To receive a firm EXW, FOB, or CIF quote within 24 hours, please provide: rated capacity (kVA), primary/secondary voltage, frequency (50Hz/60Hz), vector group (e.g. Dyn11), cooling method (ONAN/ONAF or AN/AF), and destination port.

Transformers are packed in fumigated export-grade wooden cases with waterproof moisture barriers and internal bracing. We support EXW (Hefei factory), FOB (Shanghai/Ningbo port), and CIF to any global destination port.

Thị trường Xuất khẩu

Where 12kV High-Voltage Vacuum Circuit Breakers (VCB) Are Supplied

12kV High-Voltage Vacuum Circuit Breakers (VCB) — Get a Price

Gửi Thông Số Kỹ Thuật Của Bạn

Include capacity (kVA), rated current (A), breaking capacity (kA), indoor or outdoor pole mount, destination country, and quantity. We respond within 24 hours.