500 kVA 12kV / 24kV Three-Phase Oil-Immersed Distribution Transformer — Technical Parameters & Ratings

Chapisha Karatasi ya data ya Uwasilishaji IEC / ANSI Imethibitishwa Kiwango cha Kiwanda
Uwezo Uliokadiriwa 500 kVA
Voltage ya Msingi 12 kV / 24 kV
Voltage ya Sekondari 400 V / 230 V
Mzunguko 50 Hz
Idadi ya Awamu 3-Phase
Kikundi cha Vekta Dyn11
Aina ya Kupoeza ONAN
Kiwango IEC 60076 / SEC Chile
Uzuiaji wa Mzunguko Mfupi 4.0% / 6.0%
Nyenzo za Msingi High-Permeability Grain-Oriented Silicon Steel

Uwasilishaji wa Uhandisi na Dawati la Kazi la Mpangilio

Kufaa kwa Chumba cha Kituo na Alama za CAD za Vifaa Vingi

Chagua aina ya kifaa chako na uwezo wa kukagua michoro ya laini ya CAD ya uhandisi wa GA iliyothibitishwa, Michoro ya Line Moja (SLD), vipimo (L × W × H), upimaji wa roli, na vibali vya kuwasilisha kabla ya ununuzi.

Ukadiriaji unaopatikana:
Vipimo vya Uwasilishaji vya IEC 60076-1
Mchoro wa GA CAD wa Uhandisi wa XinHuan
Mchoro wa Mstari Mmoja (SLD) wa Uhandisi wa XinHuan
Voltage Mbili ya 11kV / 33kV
Inatii IEC 60076 / IEEE
Imepimwa 100% kwa Kiwanda cha Kawaida
Usafirishaji wa Naitrojeni / Ufungashaji wa Baharini

Vipimo vya Kiufundi vya 1000 kVA

IEC 60076-1

Uainishaji wa uwasilishaji wa huduma za kimataifa na viwanda

Urefu wa Jumla (L) 1,750 mm
Upana wa Jumla (W) 1,120 mm
Urefu wa Jumla (H) 1,780 mm
Kipimo cha Reli ya Gurudumu (D) 820 mm
Uzito wa Jumla wa Vifaa 3,820 kg
Umbali wa Chini wa Kituo Kidogo 1,000 mm kuzunguka
Voltage Iliyokadiriwa / Mfumo 11 kV / 33 kV Msingi Miwili
Kiwango Kinachotumika IEC 60076-1 / IEEE C57
Pakua Karatasi ya Data ya Kiufundi (PDF) Omba Kifurushi cha Uwasilishaji wa Uhandisi wa Kiwanda

Alama kamili za vekta za CAD DXF/DWG, miundo ya 3D STEP, na uwasilishaji maalum wa miradi hutolewa ndani ya saa 2 unapoomba.

PSCAD™ & ETAP® Uigaji wa Gridi

Mkondo wa Kueneza wa V-I usio na Mstari na Uingizaji hewa wa Msingi (\(L_{\text{air}}\))

Sifa za usahihi za msisimko, mkato wa goti usio na mstari (\(V_k\)), na mwitikio wa hewa-msingi (\(X_{\text{air}}\)) umesawazishwa kwa 500 kVA 12kV / 24kV Three-Phase Oil-Immersed Distribution Transformer.

Suite Kamili ya Uhandisi
Badili ya Ukadiriaji wa Haraka
kVA
kV
%
2.10
1.80 (Komba Fiche) 2.10 (IEEE ya Kawaida / CIGRE) 2.50 (Tabaka la Nje la HV)
Uingizaji hewa wa Msingi (\(L_{\text{air}}\)) 18.7× Katika Kilele
81.65 mH
Mwitikio
25.65 Ω
Goti \(V_k\)
13.0 kV
Kuoza \(\tau\)
0.17 s
Omba Msisimko wa Kiwanda Ulioidhinishwa na Uwasilishaji wa Inrush
Sifa ya Usumaku Isiyo ya Linear (\(\lambda - I_{\text{exc}}\)) Kiwanja cha Vekta inayoingiliana
Linear Core Zone Mpito wa goti Mteremko wa Air-Core (\(X_{\text{air}}\))
Sehemu ya Kuiga ya PSCAD Voltage (\(V_{\text{pu}}\)) Flux (\(\lambda\), Wb-t) Ya sasa (\(I_{\text{pu}}\)) Ya sasa (A)
Data iliyoumbizwa ili ingizwe moja kwa moja kwenye Kibadilishaji Kigeuzi cha Kawaida cha PSCAD na vipengee vya msingi vya UMEC kwa kila IEEE C57.12.00 & CIGRE 33.02.
500 kVA 12kV / 24kV Three-Phase Oil-Immersed Distribution Transformer — XinHuan Oil-Immersed Transformer Core Stacking & Winding Workshop
Kiwanda cha Utengenezaji cha XinHuan Hefei — Upepo wa Usahihi & Mstari wa Kusanyiko

KIWANDA KUJENGA UBORA

500 kVA 12kV / 24kV Three-Phase Oil-Immersed Distribution Transformer — Internal Construction & Premium Materials

Imejengwa kwa malighafi iliyoidhinishwa ya daraja la 1 iliyobuniwa kwa muda mrefu wa kufanya kazi (zaidi ya miaka 30), uwezo wa hali ya juu wa kustahimili umeme wa dielectric, na uwezo wa juu wa kustahimili mzunguko mfupi.

Silicon Steel Core

Chuma cha silikoni kilichoviringishwa kwa kiwango cha juu cha nafaka chenye mwelekeo wa juu wa nafaka chenye viungio vya ngazi kwa hasara ya chini ya $P_o$.

100% Windings ya shaba

Shaba isiyo na oksijeni ya kielektroniki na insulation ya kiwango cha juu cha joto kwa ukinzani wa kuongezeka.

Precision Bomba Changer

Swichi ya kugusa isiyo na nishati ($\pm 2 \mara 2.5\%$) au kibadilisha utupu unapopakia (OLTC) ni hiari.

Ulinzi & Sensorer

relay ya gesi ya Buchholz, kipimo cha mafuta sumaku (MOG), na vipima joto vyenye viambatisho vya kengele.

UHAKIKISHO WA UBORA

500 kVA 12kV / 24kV Three-Phase Oil-Immersed Distribution Transformer — 100% Factory Acceptance Testing (FAT)

CNAS & ISO 9001 Imethibitishwa

Kila kitengo cha transfoma kinachotengenezwa na XinHuan hupitia majaribio ya lazima ya kiwandani kabla ya kutumwa kwa kontena. Ratiba kamili iliyoidhinishwa na ripoti za uwasilishaji za jaribio la aina hutolewa na hati za kibiashara:

1. Upinzani wa insulation

Jaribio la Megger (HV hadi LV, HV hadi Dunia, LV hadi Dunia) >1000 MΩ.

2. Uwiano wa Voltage & Vector

Hubadilisha hundi ya uwiano kwenye migongo yote kwa kuangalia uhamishaji wa awamu.

3. Upinzani wa Upepo wa DC

Usahihi wa kipimo cha daraja la Kelvin kwenye nafasi zote za bomba.

4. Uzuiaji wa Mzunguko Mfupi

Kipimo cha kupoteza mzigo ($P_k$) kimesahihishwa hadi halijoto ya marejeleo (75°C).

5. Hakuna Kupoteza Mzigo & Sasa

Jaribio la msisimko wa msingi ($P_o$ na $I_o$) katika volti iliyokadiriwa ya sinusoidal.

6. AC Voltage Kuhimili

Jaribio la chanzo tofauti cha masafa ya nishati (k.m. 50kV/70kV dak 1).

7. Msukumo wa Umeme (BIL)

Wimbi kamili na msukumo wa mawimbi yaliyokatwakatwa (BIL hadi 170kV).

8. Kutokwa kwa Sehemu & Mihuri

Utoaji wa kiwango cha chini zaidi (<5 pC) na mtihani wa kubana kwa mafuta/gesi kwa shinikizo.

AKILI YA LOGISTICS

500 kVA 12kV / 24kV Three-Phase Oil-Immersed Distribution Transformer — Export Packaging & Seaport Logistics

Utoaji wa Kimataifa wa CIF / FOB

Seaworthy wooden case / container shipping with 24h drawing delivery

Wakati wa Uzalishaji wa Uzalishaji

Mzunguko wa kawaida wa utengenezaji ni Wiki 4 hadi 6 kutoka kwa idhini ya mipango ya GA na michoro ya mstari mmoja.

Ufungaji wa Usafirishaji Mzito

Uhifadhi wa vizuizi vya unyevunyevu ombwe, blanketi ya nitrojeni, na utelezi wa kreti za muundo wa chuma-iliyoimarishwa.

Njia za Bahari ya moja kwa moja

Usafirishaji wa haraka wa baharini kwenda Bandari ya Chancay na Callao (siku 25-35), Manila, Lagos, na bandari za Mashariki ya Kati.

Ukaguzi wa Video wa Vifaa

100% Imepimwa

Tazama mafundi wa XinHuan wakifanya upimaji wa kawaida wa dielectri, ukaguzi wa insulation ya vilima, na ukaguzi wa ubora ndani ya kiwanda chetu cha kutengeneza Hefei.

Kila kitengo 100% utaratibu wa kawaida kujaribiwa kabla ya kupakia kontena.

USHAURI WA KIWANDA MOJA KWA MOJA

Je, unahitaji Uhandisi wa Mradi Maalum?

Tuma mchoro wako wa mstari mmoja (SLD), ukadiriaji wa voltage, au vipimo vya zabuni. Wahandisi wetu wakuu wa umeme watakagua na kutoa nukuu ya CIF inayoweza kutekelezeka ndani ya saa 24.

Viwango Maalum vya Voltage
Upungufu wa Urefu wa Juu
Uzuiaji wa Mzunguko Mfupi
Shahidi wa chama cha tatu FAT

500 kVA 12kV / 24kV Three-Phase Oil-Immersed Distribution Transformer — Engineering & Procurement FAQs

Maswali yanayoulizwa mara kwa mara kuhusu vipimo, vyeti na utoaji wa 500 kVA 12kV / 24kV Three-Phase Oil-Immersed Distribution Transformer.

Request / Spec & Quote

IEC 60076, SEC Chile, ISO 9001

Muda wa kawaida wa utengenezaji ni wiki 4 hadi 6 baada ya kuidhinishwa kwa ramani za GA na michoro ya mstari mmoja. Usafirishaji wa moja kwa moja wa kontena la baharini unapatikana chini ya masharti ya FOB, CFR, au CIF yenye hati kamili za forodha (Bili ya Kupakia, Cheti cha Asili, Ripoti za Jaribio).
NGUZO YA UHANDISI WA WAZAZI IEC 60076 · 50–3150 kVA Hasara & Impedans Tables

Mwongozo wa Nguzo za Transfoma za Usambazaji wa 11kV

Linganisha upotezaji wa uwezo kamili wa kutopakia ($P_0$), upotezaji wa mzigo ($P_k$), kizuizi ($U_k\%$), uzani wa vipimo, na ustahimilivu wa majaribio ya kawaida katika miundo yote katika mfululizo huu.