Sistema de Qualidade ISO 9001:2015
Sistema de gerenciamento de qualidade certificado que abrange projeto, enrolamento de bobina, secagem a vácuo, enchimento de óleo e testes de rotina de transformadores de distribuição de 10kV–35kV.
Renewable Energy Guide
Engineering specification manual for solar PV inverter step-up transformers, wind farm collector transformers, and Battery Energy Storage System (BESS) transformers. Built to IEC 60076-16 inverter duty standards with dual/quad LV windings and C5-M anti-corrosion protection.
Solar power generation introduces unique electrical and environmental stresses compared to traditional grid transformers. Solar step-up transformers (IEC 60076-16) must operate under continuous high ambient temperatures, process high-frequency inverter harmonics, withstand DC voltage bias, and endure severe daily thermal expansion cycles.
XinHuan solar transformers step up low voltage from central solar inverters (0.6kV, 0.69kV, 0.8kV, 1.1kV) directly to medium-voltage collector grids (11kV, 20kV, 33kV, 35kV) with maximum efficiency and minimum lifetime losses.
Guaranteed performance parameters according to IEC 60076-16 at 50°C solar ambient rating. Available in Dyn11, Dy11y11 (Dual LV), or Dy11y11y11 (Quad LV) vector configurations.
| Capacidade Nominal (kVA) | Tensão AT (kV) | Tensão LV (V) | LV Winding Config | No-Load Loss (W) | Load Loss (W) | Impedância Reino Unido (%) | Método de Resfriamento |
|---|---|---|---|---|---|---|---|
| 1000 kVA | 11 / 20 / 33 / 35 | 600 / 690 / 800 | Single or Dual LV | 1,120 | 8,450 | 6.0 / 6.5 | ONAN / ONAF |
| 1600 kVA | 11 / 20 / 33 / 35 | 600 / 690 / 800 | Single or Dual LV | 1,580 | 12,200 | 6.5 / 7.0 | ONAN / ONAF |
| 2000 kVA | 11 / 20 / 33 / 35 | 600 / 690 / 800 | Dual LV (Dy11y11) | 1,890 | 14,800 | 7.0 / 8.0 | ONAN / ONAF |
| 2500 kVA | 11 / 20 / 33 / 35 | 690 / 800 / 1100 | Dual LV (Dy11y11) | 2,280 | 18,100 | 8.0 | ONAN / ONAF |
| 3150 kVA | 11 / 20 / 33 / 35 | 690 / 800 / 1100 | Dual LV (Dy11y11) | 2,760 | 21,900 | 8.0 / 9.0 | ONAN / ONAF |
| 4000 kVA | 11 / 20 / 33 / 35 | 800 / 1100 | Quad LV (Dy11y11y11) | 3,450 | 27,200 | 9.0 / 10.0 | ONAN / ONAF |
| 5000 kVA | 11 / 20 / 33 / 35 | 800 / 1100 | Quad LV (Dy11y11y11) | 4,180 | 33,500 | 10.0 | ONAN / ONAF |
| 6300 kVA | 11 / 20 / 33 / 35 | 800 / 1100 | Quad LV (Dy11y11y11) | 5,120 | 41,000 | 10.0 / 12.0 | ONAN / ONAF |
Modern solar farms utilize multiple high-capacity central inverters connected to a single transformer to lower balance-of-plant (BOP) balance sheet costs.
XinHuan solar transformers feature split low-voltage windings (Dy11y11 vector group). Each LV winding is galvanically isolated from the other, preventing circulating currents between separate inverter modules and eliminating harmonic interference across solar arrays.
PV inverters can inject slight DC offset currents into transformer windings, causing magnetic core saturation. XinHuan designs feature oversized magnetic cores with reduced flux density and grounded electrostatic copper shields between HV and LV windings to divert high-frequency switching noise.
Solar farms are predominantly constructed in desert regions with extreme UV radiation and dust storms, or coastal saline environments with aggressive salt spray.
To streamline utility-scale solar farm installation, XinHuan supplies factory-assembled Solar PV Skid Substations (Containerized Power Stations):
Pre-wired connections to 1.25MW–3.125MW central solar inverters.
Multi-winding step-up transformer (0.8kV -> 33kV / 35kV).
SF6 or Solid-insulated Ring Main Unit with VCB protection.
Calculate kVA load sizing or evaluate IEC loss cost lifecycle savings for your solar project.
Multi-winding solar step-up transformers, compact PV skids, and fast 24h drawing delivery.
Get Solar Quote →Qualidade e Conformidade
Cada transformador, subestação compacta e unidade de manobra é projetado sob sistemas de gerenciamento de qualidade ISO auditados e testado de acordo com os padrões internacionais IEC 60076 e ANSI C57.
Sistema de gerenciamento de qualidade certificado que abrange projeto, enrolamento de bobina, secagem a vácuo, enchimento de óleo e testes de rotina de transformadores de distribuição de 10kV–35kV.
Sistema de gestão ambiental que certifica conjuntos centrais com design ecológico de baixa perda, zero óleo de isolamento de PCB e controles de produção ambientalmente seguros.
Sistema de Gestão de Saúde e Segurança Ocupacional garantindo contenção de segurança em baias de testes de alta tensão e protocolos de montagem em fábrica.
Registros completos de testes de rotina e de tipo (aumento de temperatura, resistência à tensão de impulso, resistência a curto-circuito) realizados em institutos de pesquisa nacionais credenciados pelo CNAS.
Certificado de auditoria de fábrica no local pela SGS / Made-in-China, verificando instalações de fabricação, capacidade de exportação, linhas de montagem e qualificação legal.
Desempenho de fornecimento anual verificado e certificado de entrega para projetos EPC de redes elétricas no exterior e projetos de infraestrutura industrial (Moçambique, Nigéria, Quênia, SEA).